Eco Hot Water EQ 1123
Wall mounted water heater heat pump, for the production of domestic hot water.
Domestic hot water heating in heat pump mode up to 60 °C.
Integrated electric resistance, which can be activated by means of a special command placed on the control panel, to heat the water from 60 to 70 °C.
Construction
- S235 JR steel tank, 110 liter capacity, with internal inorganic enamelling treatment (vitrification)
- Insulation in high thickness rigid polyurethane foam free from CFC and HCFC
- Sheet metal casing painted with epoxy powders and ABS plastic material, white
- Protection by 1 Mg anode
- Hydraulic fittings positioned in the lower part
- Steel condenser exchanger outside the tank (not immersed in water)
- 1.5 kW electric heating element
- Rotary compressor for maximum efficiency and quietness of the unit
- Centrifugal fan
- Finned pack evaporator
- Refrigerant fluid: R134a
- Safety thermostat set at +85 °C
- ON-OFF contact to start the unit from an external switch
Standard delivery
- bracket, screws and wall plugs
- spacers for wall support
- dielectric joints
Technical data
- R134a refrigerant fluid (GWP = 1430): 650 g
- Maximum working pressure: 6 bar
- Water/air side operating limits: 5÷90 °C / -5÷43 °C
- Power supply: 230 Vac /1ph/ 50 Hz
- N° and power of electric heaters: 1 x 1.5 kW
- Maximum absorbed power: 1900 W
- Maximum current consumption: 8.3A
- Degree of protection: IPX1
- Connection attachments (lower): 1/2” male
- Dimensions W x H x D: 500 x 1407 x 520 mm
- Air ducts: Ø125 mm
- Empty weight: 72 kg
- Weight with water: 182 kg
Model | Energy efficiency class | COPDHW (Heat source: Outdoor air DB 7... | Declared load profile | Q.ty per pack. | Code |
---|---|---|---|---|---|
Model EQ 1123 | Energy efficiency class A+ (min F/max A+) | COPDHW (Heat source: Outdoor air DB 7 °C) 2,61 | Declared load profile M | Q.ty per pack. 1 pcs | Code 07239721 |
Performance in accordance with EN 16147 standard. The COP values refer to the load profile declared in the table. |