Modular Firstbox distribution module with auxiliary connections, in cabinet
Download HD imageModular Firstbox distribution module with auxiliary connections, in cabinet
Distribution system composed of a module for high temperature heating units (2 or 3) and 1 or 2 low temperature regulation units, which allow the development of high temperature and low temperature zoned systems.
The system is composed of:
- Supply manifold for radiator systems with 2 or 3 branches
- Return manifold for radiator systems with 2 or 3 branches
- Supply manifold for underfloor system
- Return manifold for underfloor system
- Fixing brackets
- 1 or 2 mixing valves ready for thermostatic head or servomotor
- 1 or 2 calibration bypass valves
- 1 or 2 Wilo Para 25/7 circulation pumps
- Lockshields
- Fill/drain valves
- Monitoring thermometers
- Box for built-in installation H 850 mm W 500 mm D 110 mm
Technical specifications:
- Maximum temperature: 90 °C
- Max operating pressure: 10 bar
- ∆pmax on primary circuit: 1 bar
- Exchangeable heat output (∆T 7 °C, ∆p effective 0.25 bar)
fixed-point regulation: 10 kW bypass pos.0
fixed-point regulation: 12.5 kW bypass pos. 5
- Mixing valve pressure drops (fixed-point regulation): Kv = 3
- Kv with bypass valve in open position: max 4.8
- Low temperature manifold head thread: 1”1/4 F
- High temperature manifold head thread: 1” F
The system is composed of:
- Supply manifold for radiator systems with 2 or 3 branches
- Return manifold for radiator systems with 2 or 3 branches
- Supply manifold for underfloor system
- Return manifold for underfloor system
- Fixing brackets
- 1 or 2 mixing valves ready for thermostatic head or servomotor
- 1 or 2 calibration bypass valves
- 1 or 2 Wilo Para 25/7 circulation pumps
- Lockshields
- Fill/drain valves
- Monitoring thermometers
- Box for built-in installation H 850 mm W 500 mm D 110 mm
Technical specifications:
- Maximum temperature: 90 °C
- Max operating pressure: 10 bar
- ∆pmax on primary circuit: 1 bar
- Exchangeable heat output (∆T 7 °C, ∆p effective 0.25 bar)
fixed-point regulation: 10 kW bypass pos.0
fixed-point regulation: 12.5 kW bypass pos. 5
- Mixing valve pressure drops (fixed-point regulation): Kv = 3
- Kv with bypass valve in open position: max 4.8
- Low temperature manifold head thread: 1”1/4 F
- High temperature manifold head thread: 1” F
To be completed with:
- thermostatic head with immersion probe cod. 90046750
or
- 3-point electric servomotor cod. 28157212
or
- 0-10 V DC electric servomotor cod. 28157222
In case of installation of an electric servomotor, combine the RCE or PCOC electronic climatic regulation kit for heating and / or cooling.
Note: for a correct recessed installation, it is recommended to install the module keeping a distance between the back of the box and the flush to the wall equal to 135 mm.
Model | Q.ty per pack. | Code | |
---|---|---|---|
Model (2+2)H + 1L | Q.ty per pack. 1 pcs | Code 28151754 | |
Model (2+2)H + 1L | Q.ty per pack. 1 pcs | Code 28151756 | |
Model (3+3)H + 2L | Q.ty per pack. 1 pcs | Code 28151758 | |
Model (3+3)H + 2L | Q.ty per pack. 1 pcs | Code 28151760 |