Silence THIN ETM, "TERMOSTATO A BORDO THIN-4-V" version
Download HD imageSilence THIN ETM, "TERMOSTATO A BORDO THIN-4-V" version
Silence THIN ETM wall-mounted fan coil unit, with cabinet, "THIN 4 V on board thermostat" version, featuring a modern design and reduced depth (130 mm), making the Silence THIN fan coil unit ideal for any space, perfectly blending in with the furniture.
It is available in different sizes depending on the requested heat output, it can be installed vertically on the wall or floor and connected to "two-pipe" systems with hot or cold water.
The "THIN-4-V" version with on-board thermostat is able to create and maintain the ideal conditions for well-being all year round, in any residential space thanks to the SMART TOUCH controller with touchpad display on the front to control the ambient temperature, fan speed (3 available speeds), operating mode, and Super Silent function which adjusts the fan speed to the minimum in cooling and radiant mode only in heating.
The fan coil unit is equipped with the latest DC-INVERTER technology with high-performance permanent magnet fan motor, with speed and power regulation through the PWM electronic device, with noise reduction and power savings of up to 50%.
Air-to-water round-tube plate-fin heat exchanger coil in copper tubing with louvred, high-efficiency aluminium fins.
Supplied with air filter and condensate drain pan in ABS, for vertical and horizontal installation.
It is available in different sizes depending on the requested heat output, it can be installed vertically on the wall or floor and connected to "two-pipe" systems with hot or cold water.
The "THIN-4-V" version with on-board thermostat is able to create and maintain the ideal conditions for well-being all year round, in any residential space thanks to the SMART TOUCH controller with touchpad display on the front to control the ambient temperature, fan speed (3 available speeds), operating mode, and Super Silent function which adjusts the fan speed to the minimum in cooling and radiant mode only in heating.
The fan coil unit is equipped with the latest DC-INVERTER technology with high-performance permanent magnet fan motor, with speed and power regulation through the PWM electronic device, with noise reduction and power savings of up to 50%.
Air-to-water round-tube plate-fin heat exchanger coil in copper tubing with louvred, high-efficiency aluminium fins.
Supplied with air filter and condensate drain pan in ABS, for vertical and horizontal installation.
Model | Total Cooling Capacity [kW] med (min - m... | Heating Capacity Prated,h [kW] med (min... | Air flow rate [m³/h] med (min - max) | Q.ty per pack. | Code | |
---|---|---|---|---|---|---|
Model ETM 220 DU | Total Cooling Capacity [kW] med (min - max) 0,61 (0,36 - 0,76) | Heating Capacity Prated,h [kW] med (min - max) 0,73 (0,38 - 0,97) | Air flow rate [m³/h] med (min - max) 90 (49 - 146) | Q.ty per pack. 1 pcs | Code 07520015 | |
Model ETM 240 DU | Total Cooling Capacity [kW] med (min - max) 1,36 (0,66 - 1,77) | Heating Capacity Prated,h [kW] med (min - max) 1,63 (0,95 - 2,18) | Air flow rate [m³/h] med (min - max) 210 (118 - 294) | Q.ty per pack. 1 pcs | Code 07520025 | |
Model ETM 260 DU | Total Cooling Capacity [kW] med (min - max) 2,16 (1,30 - 2,89) | Heating Capacity Prated,h [kW] med (min - max) 2,33 (1,24 - 3,11) | Air flow rate [m³/h] med (min - max) 318 (180 - 438) | Q.ty per pack. 1 pcs | Code 07520035 | |
Model ETM 280 DU | Total Cooling Capacity [kW] med (min - max) 2,52 (1,82 - 3,20) | Heating Capacity Prated,h [kW] med (min - max) 3,05 (1,90 - 3,88) | Air flow rate [m³/h] med (min - max) 411 (247 - 567) | Q.ty per pack. 1 pcs | Code 07520045 | |
Model ETM 220 SU | Total Cooling Capacity [kW] med (min - max) 0,61 (0,36 - 0,76) | Heating Capacity Prated,h [kW] med (min - max) 0,73 (0,38 - 0,97) | Air flow rate [m³/h] med (min - max) 90 (49 - 146) | Q.ty per pack. 1 pcs | Code 07520115 | |
Model ETM 240 SU | Total Cooling Capacity [kW] med (min - max) 1,36 (0,66 - 1,77) | Heating Capacity Prated,h [kW] med (min - max) 1,63 (0,95 - 2,18) | Air flow rate [m³/h] med (min - max) 210 (118 - 294) | Q.ty per pack. 1 pcs | Code 07520125 | |
Model ETM 260 SU | Total Cooling Capacity [kW] med (min - max) 2,16 (1,30 - 2,89) | Heating Capacity Prated,h [kW] med (min - max) 2,33 (1,24 - 3,11) | Air flow rate [m³/h] med (min - max) 318 (180 - 438) | Q.ty per pack. 1 pcs | Code 07520135 | |
Model ETM 280 SU | Total Cooling Capacity [kW] med (min - max) 2,52 (1,82 - 3,20) | Heating Capacity Prated,h [kW] med (min - max) 3,05 (1,90 - 3,88) | Air flow rate [m³/h] med (min - max) 411 (247 - 567) | Q.ty per pack. 1 pcs | Code 07520145 |
Cooling performance under the following standard nominal conditions: - internal Air temperature = 27 (19) °C - Water temperature = 7/12 °C Heating performance under the following standard nominal conditions: - internal Air temperature = 20 °C - Water temperature = 45/40 °C Information requirements for fancoils according to Regulation EU 2016/2281. Performance according to EN 1397:2016, EN 16583:2015 standards. Power supply: 230 Vac/1 ph/50 Hz. Standard water connection on the right side (DU models) or on the left side (SU models). Note: The water circulating in the exchanger must not exceed 60 °C. |